Helium leak testing equipment for Cast resin components
Double chamber system
Two-sided testing
Helium concentration optionally 50 – 100 %
Type-specific tool pickup
Manual fitting
Automatic testing sequence
Optical „Go/No-go“ indicator
Technical details:
Cycle time 45 sec. Leak rate 1.0 · 10-6 mbarl/s Test pressure 1.5 bar abs. 0 bar Helium concentration 50 - 100 % He
Helium leak testing equipment for sf6 voltage switches
Automatic SF6 charging
Helium recovery
Vacuum chamber from 1.4301
Process visualization WinCC
Data archiving of readings
Logger
Gross weight: 10 t
Dimensions: L = 10 m D = 6 m H = 4 m
Technical details:
Chamber size 7.5 m3 Pumping speed 5000 m3/h Cycle time 10 min. Leak rate 1.0 · 10-6 mbarl/s Test pressure 1.5 bar abs. 0 bar Helium concentration 100 % He
SF6 leak testing system for SF6 compressed air feed pipes
Mobile system
Automatic sequence
Integral vacuum leak test in accordance with the carrier gas principle
Vacuum bell accommodates every position on test piece
Technical details:
Cycle time 45 sec. Leak rate 1.0 · 10-6 mbarl/s Test pressure 1.5 bar abs. 0.4 bar SF6 concentration 100% SF6